Cable Electrical Armoured and Non Armoured for Russia
Description |
CBL ELEC ARM,0.6/1KV,4CX150MM² Cable, Electrical, Armoured Voltage 0.6 / 1 kV Construction Cu/XLPE/SHF1/SWA/SHF1 Identification, cores #NAME? BROWN(L1), BLACK(L2), GREY(L3) Number, cores 4 Cross section, cores 150 mm² Diameter, od, overall NOTE LESS 52.1 MM (MIN) 59.4 MM (MAX) Mat, insulation XLPE Mat, armour bending SHF1 Mat, armour GSWA Diameter, under armour 40.1 mm (MIN) 49.9 mm (MAX) Number of wire 53 Diameter, wire 2.5 mm Color, sheath BLACK Weigh 9100 kgs/km Bending radius 476 mm Resistance, conductor 0.124 ohm/km AT 20 °C Reactance 0.074 ohm/km AT 50 Hz Current rating, air 399 A AT 30 °C (ADMISSIBLE SUSTAINED) 287 A AT 20 °C (DIRECTLY BURIED) Temperature rating, conductor 90 / 250 °C Climate application HL/UHL 1 GOST 15150 Temperature rating , ambient -50 / +50 °C Relative humidity 95 % AT 25 °C Installation temperature -30 °C (WITHOUT PRE-HEATING) Service life 30 YR (MIN) Warranty rated life 5 YR Size, glanding 25 Bedding diameter range 18.2 TO 26.2 mm Armor range 0.4 TO 1.6 mm (GSWA) Compliance with regulatory requirements IEC 60502-1/GOST 31996 IEC 61034-2/GOST IEC 61034-2 (MINIMUM LIGHT TRANSMISSION VALUE OF 60%) IEC 60754-1 /GOST IEC 60754-1 (MAXIMUM HALOGEN GAS EMISSION OF 0.5%) IEC 60754-2 / GOST IEC 60754-2(index pH ≥ 4.3, conductivity ≤ 10 μS.mm-1) IEC 60684-2 (maximum fluorine emission 0.1%) IEC 60332-3-22 / ГОСТ IEC 60332-3-22(flame retardant cable, category A) IEC 60079-14 / GOST IEC 60079-14 and GOST R 58342 (for cable use in hazardous classified areas) Notes: 1. Any deviations from the stated requirements must be communicated to the Customer and agreed. 2. Cable fillers shall be solid, non-hygroscopic and fill the cross-section such that the transmission of gas or hydrocarbons along the length of the cable, under pressure, is not possible 3. Installation Method E (МЭК60364-5-52 / GOST R 50571-5-52) for Three loaded conductors in air, at 30 C 4. Installation Method D2 (МЭК60364-5-52 /GOST R 50571-5-52) for Sheathed Single core or Multi core cables directly buried in the ground, at 20 C, thermal resistivity 1.5 Km/W, depth of laying 0.7m 5. Maximum drum diameter, 2 m 6.Minimum radius of the cable drum core, 250 mm 7.This cable can be used with cable gland triton, manufacturer CMP. Compliance internal requirements of company Sakhalin Energy: 1000-S-40-68-S-0003-00 Technical specification for electric cable / wires & glands onshore Outer sheath shall be highly resistant to mud, ultra-violet radiation and airborne contaminants associated with petrochemical installations. Mat, insulation XLPE Mat, armour bending SHF1 Mat, armour GSWA Diameter, under armour 40.1 mm (MIN) 49.9 mm (MAX) Number of wire 53 Diameter, wire 2.5 mm Color, sheath BLACK Weigh 9100 kgs/km Bending radius 476 mm Resistance, conductor 0.124 ohm/km AT 20 °C Reactance 0.074 ohm/km AT 50 Hz Current rating, air 399 A AT 30 °C (ADMISSIBLE SUSTAINED) 287 A AT 20 °C (DIRECTLY BURIED) Temperature rating, conductor 90 / 250 °C Climate application HL/UHL 1 GOST 15150 Temperature rating , ambient -50 / +50 °C Relative humidity 95 % AT 25 °C Installation temperature -30 °C (WITHOUT PRE-HEATING) Service life 30 YR (MIN) Warranty rated life 5 YR Size, glanding 25 Bedding diameter range 18.2 TO 26.2 mm Armor range 0.4 TO 1.6 mm (GSWA) Compliance with regulatory requirements IEC 60502-1/GOST 31996 IEC 61034-2/GOST IEC 61034-2 (MINIMUM LIGHT TRANSMISSION VALUE OF 60%) IEC 60754-1 /GOST IEC 60754-1 (MAXIMUM HALOGEN GAS EMISSION OF 0.5%) IEC 60754-2 / GOST IEC 60754-2(index pH ≥ 4.3, conductivity ≤ 10 μS.mm-1) IEC 60684-2 (maximum fluorine emission 0.1%) IEC 60332-3-22 / ГОСТ IEC 60332-3-22(flame retardant cable, category A) IEC 60079-14 / GOST IEC 60079-14 and GOST R 58342 (for cable use in hazardous classified areas) Notes: 1. Any deviations from the stated requirements must be communicated to the Customer and agreed. 2. Cable fillers shall be solid, non-hygroscopic and fill the cross-section such that the transmission of gas or hydrocarbons along the length of the cable, under pressure, is not possible 3. Installation Method E (МЭК60364-5-52 / GOST R 50571-5-52) for Three loaded conductors in air, at 30 C 4. Installation Method D2 (МЭК60364-5-52 /GOST R 50571-5-52) for Sheathed Single core or Multi core cables directly buried in the ground, at 20 C, thermal resistivity 1.5 Km/W, depth of laying 0.7m 5. Maximum drum diameter, 2 m 6.Minimum radius of the cable drum core, 250 mm 7.This cable can be used with cable gland triton, manufacturer CMP. Compliance internal requirements of company Sakhalin Energy: 1000-S-40-68-S-0003-00 Technical specification for electric cable / wires & glands onshore Outer sheath shall be highly resistant to mud, ultra-violet radiation and airborne contaminants associated with petrochemical installations. VENDOR DOCUMENT REQUIREMENTS: A01 Vendor Master Data Schedule (VMDS) H18 Catalogue Data K03 Performance Test Results K38 CU TR Certificate , Declaration of Conformity for Low Voltage Equipment K39 RF , CU TR Fire Safety Certificate of Conformity L04 Quality Management Accreditation (including any manufacturing licenses held by Vendor, e.g. API, ASME etc.) P06 Preparation for Shipping with Recommended Handling, Storage & Preservation Procedures |
CBL ELEC N-ARM,CU,PVC,1X6MM²,BL Cable, Electrical, Non armoured Voltage 0.45 / 0.75 kV Mat, conductor COPPER Mat spec, insulation PVC Colour, outer sheath BLUE Number, cores 1 Cross section, cores 6 mm² Diameter, od, overall 6.5 mm Shape, conductor CIRCULAR Class 5 (BS EN 60228 / GOST 22483) Mat, outer sheath PVC Dia, overall 6.5 mm Weight 85 kg/km Bending radius no more 5XD 32.5 mm (APPROXIMATE) Resistance, conductor dc 3.08 ohm/km AT 20 °C (IEC 60228/GOST 22483) Current, admissible sustained in air 48 A(AT 30 °C) Current, admissible sustained directly buried 41 A (AT 20 °C) Temp, conductor 160 °C (IN SHORT-CIRCUIT) CLIMATE APPLICATION GOST 15150 Temp range, ambient -50 TO +50 °C Humidity, relative at 25 °C 95% Temperature, installation -15 °C WITHOUT PRE-HEATING Service life 30 YR The outer sheath of cable shall be an extruded layer of shf1 or any other thermoplastic pvc, intrinsically flame retardant, low smoke, oil and uv resistant and antitermite protected that is suitable for the cold operating temperature Compliance internal requirements of company sakhalin energy: 1. 1000-S-40-68-S-0003-00 technical specification for electric cables / wires & glands onshore Compliance with regulatory requirements: 1.IEC 60227-1 / GOST IEC 60227-1 (OR GOST 31947 AS agreed with the customer) 2.IEC 61034-2 / GOST IEC 61034-2 (minimum light transmission value of 60%) 3.IEC 60754-1 / GOST IEC 60754-1 (maximum halogen gas emission of 0.5%) 4.IEC 60754-2 / GOST IEC 60754-2 (index PH >= 4.3, conductivity <=10 ΜS.MM-1) 5.IEC 60684-2 (maximum fluorine emission 0.1%) 6.IEC 60332-3-22 / ГОСТ IEC 60332-3-22(flame retardant cable, category A) NOTES: 1. Any deviations from the stated requirements must be communicated to the customer and agreed. 2. Installation method e (МЭК60364-5-52 / GOST R 50571-5-52) for three loaded conductors in air 3. Installation method d2 (МЭК60364-5-52 / GOSTR50571-5-52) for sheathed single core or multi core cables directly buried in the ground, at 20 °C, thermal resistivity 1.5 KxM/W, DEPTH OF LAYING 0.7 m 4. Maximum drum diameter, m 2 minimum radius of the cable drum core, mm 100 Shape, conductor CIRCULAR Class 5 (BS EN 60228 / GOST 22483) Mat, outer sheath PVC Dia, overall 6.5 mm Weight 85 kg/km Bending radius no more 5XD 32.5 mm (APPROXIMATE) Resistance, conductor dc 3.08 ohm/km AT 20 °C (IEC 60228/GOST 22483) Current, admissible sustained in air 48 A(AT 30 °C) Current, admissible sustained directly buried 41 A (AT 20 °C) Temp, conductor 160 °C (IN SHORT-CIRCUIT) CLIMATE APPLICATION GOST 15150 Temp range, ambient -50 TO +50 °C Humidity, relative at 25 °C 95% Temperature, installation -15 °C WITHOUT PRE-HEATING Service life 30 YR The outer sheath of cable shall be an extruded layer of shf1 or any other thermoplastic pvc, intrinsically flame retardant, low smoke, oil and uv resistant and antitermite protected that is suitable for the cold operating temperature Compliance internal requirements of company sakhalin energy: 1. 1000-S-40-68-S-0003-00 technical specification for electric cables / wires & glands onshore Compliance with regulatory requirements: 1.IEC 60227-1 / GOST IEC 60227-1 (OR GOST 31947 AS agreed with the customer) 2.IEC 61034-2 / GOST IEC 61034-2 (minimum light transmission value of 60%) 3.IEC 60754-1 / GOST IEC 60754-1 (maximum halogen gas emission of 0.5%) 4.IEC 60754-2 / GOST IEC 60754-2 (index PH >= 4.3, conductivity <=10 ΜS.MM-1) 5.IEC 60684-2 (maximum fluorine emission 0.1%) 6.IEC 60332-3-22 / ГОСТ IEC 60332-3-22(flame retardant cable, category A) NOTES: 1. Any deviations from the stated requirements must be communicated to the customer and agreed. 2. Installation method e (МЭК60364-5-52 / GOST R 50571-5-52) for three loaded conductors in air 3. Installation method d2 (МЭК60364-5-52 / GOSTR50571-5-52) for sheathed single core or multi core cables directly buried in the ground, at 20 °C, thermal resistivity 1.5 KxM/W, DEPTH OF LAYING 0.7 m 4. Maximum drum diameter, m 2 minimum radius of the cable drum core, mm 100 Recommended for purchase in Russian Federation VENDOR DOCUMENT REQUIREMENTS: A01 Vendor Master Data Schedule (VMDS) H18 Catalogue Data K03 Performance Test Results K38 CU TR Certificate , Declaration of Conformity for Low Voltage Equipment K39 RF , CU TR Fire Safety Certificate of Conformity L04 Quality Management Accreditation (including any manufacturing licenses held by Vendor, e.g. API, ASME etc.) P06 Preparation for Shipping with Recommended Handling, Storage & Preservation Procedures |
CBL ELEC N-ARM FIRE,0.75KV,1X4MM²,BLK Fire spec non armoured electrical cable Flammability properties FLAME RETANDANT Voltage 0.45/0.75 kV Construction Cu/LSHF Mat, conductor wire UNCOATED ANNEALED COPPER Mat spec, insulation LSHF Identification, cores BLACK Number, cores 1 Cross section, cores 4 mm² Diameter, od, overall 3.9 TO 4.8 mm Frequency, nominal UP TO 400 Hz Shape CIRCULAR Class 5 Standard IEC 60228/GOST 22483 Resistance, conductor DC, max 4.95 ohm/km AT 20 °C Reactance, approx 0.098 ohm/km AT 50 Hz Current rating, short-circuit 1.36/0.61/0.43 kA (0.1/0.5/1.0 s) Temperature rating, conductor 70 °C (OPERATING) 160 °C (SHORT CIRCUIT) Test voltage 2500 Vac Temperature range , ambient -50 TO +50 °C Tensile strength 9.0 N/mm² (NOT LESS THAN) Bending radius 8 x D (MIN) Relative humidity 98% AT 35 °C Installation temperature -15 °C (WITHOUT PRE-HEATING) Nominal tensile load 14.7 N Weight, approximate 50 kgs/km Service life 20 YR (MIN) Warranty rated life 3 YR (MIN) Current rating 34 А (IEC 60364-5-52 / GOST R 50571-5-52) Fire safety requirements: 1. Fire hazard category (cable marking) А 2. The toxicity index of combustion products > 40 g/m³ 2. Smoke Density (minimum light transmission) > 60% Resistance to external factors: Climatic modification and placement category HL/UHL 1 GOST 15150 By agreement with the customer, it is allowed to change the climatic modification and placement category depending on the laying conditions Resistance to alternating bending deformations, cycles (movements), not less than Operation requirements: 1. Place of operation: Onshore technological complexes the cables in all respects, be suitable for operation in conditions prevailing within a typical petrochemical facility and the stated service conditions where the atmosphere shall be regarded as saliferous and corrosive, as commonly encountered in installations in close proximity to the 2. Appointment: The wires are intended for distribution of electric energy in the electric installations at stationary laying in lighting and power electric networks as well as for installation of electrical equipment, machines, tools and other machines, indoor electric settings Compliance with regulatory requirements: 1. IEC 60227-3 / GOST IEC 60227-3 or GOST 31947 (Requirements for the construction, size and testing) 2. IEC 60332 - 3-22/ GOST IEC 60332-3-22 (flame spread test on bunched cables) 3. EN 50305/GOST 12.1.044 (Checking the toxicity index of combustion products) 4. IEC 61034-2/ GOST IEC 61034-2 (Smoke emission test) 5. The tests at low temperature shall be done in accordance with IEC 60811-506 for cold impact and IEC 60811-504 for cold bending or IEC 60811-505 for elongation at break when the cable is not subjected to bending test. The tests shall be carried out at a test temperature of (-45 +/- 2) °C for the cold bending and at (-40 +/- 2) °C for the cold impact test. Notes: 1. Any deviations from the stated requirements must be communicated to the Customer and agreed. 2. Manufacturer shall list in his quotation the type tests and routine tests to which his cables are Subjected Abbreviations: 1. Cu - сopper 2. LSHF - extruded layer of halogen free low smoke thermoplastic compound based on polymer compositions Type tests: Tests made before supplying, on a general commercial basis, a type of cable covered by this standard, in order to demonstrate satisfactory performance characteristics to meet the intended application Routine tests: Tests made by the manufacturer on each manufactured length of cable to check that each length meets the specified requirements Frequency, nominal UP TO 400 Hz Shape CIRCULAR Class 5 Standard IEC 60228/GOST 22483 Resistance, conductor DC, max 4.95 ohm/km AT 20 °C Reactance, approx 0.098 ohm/km AT 50 Hz Current rating, short-circuit 1.36/0.61/0.43 kA (0.1/0.5/1.0 s) Temperature rating, conductor 70 °C (OPERATING) 160 °C (SHORT CIRCUIT) Test voltage 2500 Vac Temperature range , ambient -50 TO +50 °C Tensile strength 9.0 N/mm² (NOT LESS THAN) Bending radius 8 x D (MIN) Relative humidity 98% AT 35 °C Installation temperature -15 °C (WITHOUT PRE-HEATING) Nominal tensile load 14.7 N Weight, approximate 50 kgs/km Service life 20 YR (MIN) Warranty rated life 3 YR (MIN) Current rating 34 А (IEC 60364-5-52 / GOST R 50571-5-52) Fire safety requirements: 1. Fire hazard category (cable marking) А 2. The toxicity index of combustion products > 40 g/m³ 2. Smoke Density (minimum light transmission) > 60% Resistance to external factors: Climatic modification and placement category HL/UHL 1 GOST 15150 By agreement with the customer, it is allowed to change the climatic modification and placement category depending on the laying conditions Resistance to alternating bending deformations, cycles (movements), not less than Operation requirements: 1. Place of operation: Onshore technological complexes the cables in all respects, be suitable for operation in conditions prevailing within a typical petrochemical facility and the stated service conditions where the atmosphere shall be regarded as saliferous and corrosive, as commonly encountered in installations in close proximity to the 2. Appointment: The wires are intended for distribution of electric energy in the electric installations at stationary laying in lighting and power electric networks as well as for installation of electrical equipment, machines, tools and other machines, indoor electric settings Compliance with regulatory requirements: 1. IEC 60227-3 / GOST IEC 60227-3 or GOST 31947 (Requirements for the construction, size and testing) 2. IEC 60332 - 3-22/ GOST IEC 60332-3-22 (flame spread test on bunched cables) 3. EN 50305/GOST 12.1.044 (Checking the toxicity index of combustion products) 4. IEC 61034-2/ GOST IEC 61034-2 (Smoke emission test) 5. The tests at low temperature shall be done in accordance with IEC 60811-506 for cold impact and IEC 60811-504 for cold bending or IEC 60811-505 for elongation at break when the cable is not subjected to bending test. The tests shall be carried out at a test temperature of (-45 +/- 2) °C for the cold bending and at (-40 +/- 2) °C for the cold impact test. Notes: 1. Any deviations from the stated requirements must be communicated to the Customer and agreed. 2. Manufacturer shall list in his quotation the type tests and routine tests to which his cables are Subjected Abbreviations: 1. Cu - сopper 2. LSHF - extruded layer of halogen free low smoke thermoplastic compound based on polymer compositions Type tests: Tests made before supplying, on a general commercial basis, a type of cable covered by this standard, in order to demonstrate satisfactory performance characteristics to meet the intended application Routine tests: Tests made by the manufacturer on each manufactured length of cable to check that each length meets the specified requirements Recommended for purchase in Russian Federation VENDOR DOCUMENT REQUIREMENTS: A01 Vendor Master Data Schedule (VMDS) B07 Vendor's Declaration of Compliance H18 Catalogue Data K04 Factory Acceptance Test (FAT) Report K38 CU TR Certificate , Declaration of Conformity for Low Voltage Equipment K39 RF , CU TR fire Safety Certificate of Conformity L04 Quality Management Accreditation eg ISO 9000 (including any manufacturing licenses held by Vendor, e.g. API, ASME etc.) N01 Installation, Commissioning, Operating & Maintenance Manuals P06 Preparation for Shipping with Recommended Handling, Storage & Preservation Procedures |
CBL ELEC N-ARM FIRE,0.75KV,1X4MM²,BL Fire spec non armoured electrical cable Flammability properties FLAME RETANDANT Voltage 0.45/0.75 kV Construction Cu/LSHF Mat, conductor wire UNCOATED ANNEALED COPPER Mat spec, insulation LSHF Identification, cores BLUE Number, cores 1 Cross section, cores 4 mm² Diameter, od, overall 3.9 TO 4.8 mm Frequency, nominal UP TO 400 Hz Shape CIRCULAR Class 5 Standard IEC 60228/GOST 22483 Resistance, conductor DC, max 4.95 ohm/km AT 20 °C Reactance, approx 0.098 ohm/km AT 50 Hz Current rating, short-circuit 1.36/0.61/0.43 kA (0.1/0.5/1.0 s) Temperature rating, conductor 70 °C (OPERATING) 160 °C (SHORT CIRCUIT) Test voltage 2500 Vac Temperature range , ambient -50 TO +50 °C Tensile strength 9.0 N/mm² (NOT LESS THAN) Bending radius 8 x D (MIN) Relative humidity 98% AT 35 °C Installation temperature -15 °C (WITHOUT PRE-HEATING) Nominal tensile load 14.7 N Weight, approximate 50 kgs/km Service life 20 YR (MIN) Warranty rated life 3 YR (MIN) Current rating 34 А (IEC 60364-5-52 / GOST R 50571-5-52) Fire safety requirements: 1. Fire hazard category (cable marking) А 2. The toxicity index of combustion products > 40 g/m³ 2. Smoke Density (minimum light transmission) > 60% Resistance to external factors: Climatic modification and placement category HL/UHL 1 GOST 15150 By agreement with the customer, it is allowed to change the climatic modification and placement category depending on the laying conditions Resistance to alternating bending deformations, cycles (movements), not less than Operation requirements: 1. Place of operation: Onshore technological complexes the cables in all respects, be suitable for operation in conditions prevailing within a typical petrochemical facility and the stated service conditions where the atmosphere shall be regarded as saliferous and corrosive, as commonly encountered in installations in close proximity to the 2. Appointment: The wires are intended for distribution of electric energy in the electric installations at stationary laying in lighting and power electric networks as well as for installation of electrical equipment, machines, tools and other machines, indoor electric settings Compliance with regulatory requirements: 1. IEC 60227-3 / GOST IEC 60227-3 or GOST 31947 (Requirements for the construction, size and testing) 2. IEC 60332 - 3-22/ GOST IEC 60332-3-22 (flame spread test on bunched cables) 3. EN 50305/GOST 12.1.044 (Checking the toxicity index of combustion products) 4. IEC 61034-2/ GOST IEC 61034-2 (Smoke emission test) 5. The tests at low temperature shall be done in accordance with IEC 60811-506 for cold impact and IEC 60811-504 for cold bending or IEC 60811-505 for elongation at break when the cable is not subjected to bending test. The tests shall be carried out at a test temperature of (-45 +/- 2) °C for the cold bending and at (-40 +/- 2) °C for the cold impact test. Notes: 1. Any deviations from the stated requirements must be communicated to the Customer and agreed. 2. Manufacturer shall list in his quotation the type tests and routine tests to which his cables are Subjected Abbreviations: 1. Cu - сopper 2. LSHF - extruded layer of halogen free low smoke thermoplastic compound based on polymer compositions Type tests: Tests made before supplying, on a general commercial basis, a type of cable covered by this standard, in order to demonstrate satisfactory performance characteristics to meet the intended application Routine tests: Tests made by the manufacturer on each manufactured length of cable to check that each length meets the specified requirements Frequency, nominal UP TO 400 Hz Shape CIRCULAR Class 5 Standard IEC 60228/GOST 22483 Resistance, conductor DC, max 4.95 ohm/km AT 20 °C Reactance, approx 0.098 ohm/km AT 50 Hz Current rating, short-circuit 1.36/0.61/0.43 kA (0.1/0.5/1.0 s) Temperature rating, conductor 70 °C (OPERATING) 160 °C (SHORT CIRCUIT) Test voltage 2500 Vac Temperature range , ambient -50 TO +50 °C Tensile strength 9.0 N/mm² (NOT LESS THAN) Bending radius 8 x D (MIN) Relative humidity 98% AT 35 °C Installation temperature -15 °C (WITHOUT PRE-HEATING) Nominal tensile load 14.7 N Weight, approximate 50 kgs/km Service life 20 YR (MIN) Warranty rated life 3 YR (MIN) Current rating 34 А (IEC 60364-5-52 / GOST R 50571-5-52) Fire safety requirements: 1. Fire hazard category (cable marking) А 2. The toxicity index of combustion products > 40 g/m³ 2. Smoke Density (minimum light transmission) > 60% Resistance to external factors: Climatic modification and placement category HL/UHL 1 GOST 15150 By agreement with the customer, it is allowed to change the climatic modification and placement category depending on the laying conditions Resistance to alternating bending deformations, cycles (movements), not less than Operation requirements: 1. Place of operation: Onshore technological complexes the cables in all respects, be suitable for operation in conditions prevailing within a typical petrochemical facility and the stated service conditions where the atmosphere shall be regarded as saliferous and corrosive, as commonly encountered in installations in close proximity to the 2. Appointment: The wires are intended for distribution of electric energy in the electric installations at stationary laying in lighting and power electric networks as well as for installation of electrical equipment, machines, tools and other machines, indoor electric settings Compliance with regulatory requirements: 1. IEC 60227-3 / GOST IEC 60227-3 or GOST 31947 (Requirements for the construction, size and testing) 2. IEC 60332 - 3-22/ GOST IEC 60332-3-22 (flame spread test on bunched cables) 3. EN 50305/GOST 12.1.044 (Checking the toxicity index of combustion products) 4. IEC 61034-2/ GOST IEC 61034-2 (Smoke emission test) 5. The tests at low temperature shall be done in accordance with IEC 60811-506 for cold impact and IEC 60811-504 for cold bending or IEC 60811-505 for elongation at break when the cable is not subjected to bending test. The tests shall be carried out at a test temperature of (-45 +/- 2) °C for the cold bending and at (-40 +/- 2) °C for the cold impact test. Notes: 1. Any deviations from the stated requirements must be communicated to the Customer and agreed. 2. Manufacturer shall list in his quotation the type tests and routine tests to which his cables are Subjected Abbreviations: 1. Cu - сopper 2. LSHF - extruded layer of halogen free low smoke thermoplastic compound based on polymer compositions Type tests: Tests made before supplying, on a general commercial basis, a type of cable covered by this standard, in order to demonstrate satisfactory performance characteristics to meet the intended application Routine tests: Tests made by the manufacturer on each manufactured length of cable to check that each length meets the specified requirements Recommended for purchase in Russian Federation VENDOR DOCUMENT REQUIREMENTS: A01 Vendor Master Data Schedule (VMDS) B07 Vendor's Declaration of Compliance H18 Catalogue Data K04 Factory Acceptance Test (FAT) Report K38 CU TR Certificate , Declaration of Conformity for Low Voltage Equipment K39 RF , CU TR fire Safety Certificate of Conformity L04 Quality Management Accreditation eg ISO 9000 (including any manufacturing licenses held by Vendor, e.g. API, ASME etc.) N01 Installation, Commissioning, Operating & Maintenance Manuals P06 Preparation for Shipping with Recommended Handling, Storage & Preservation Procedures |
CBL ELEC N-ARM FIRE,0.38/0.66KV,3X1.5MM² Fire spec non armoured electrical cable Flammability properties FLAME RETANDANT Voltage 0.38/0.66 kV Construction Cu/PVC/PVC Mat, conductor wire UNCOATED ANNEALED COPPER Mat spec, insulation PVC Mat spec, outer sheath PVC Colour, outer sheath BLACK Identification, cores BROWN(L), BLUE(L) + GREEN/YELLOW(EARTH) Number, cores 3 Cross section, cores 1.5 mm² Diameter, od, overall 7.4 TO 9.4 mm Frequency, nominal 50 Hz Shape CIRCULAR Class 5 Standard IEC 60228/GOST 22483 Resistance, conductor DC, max 13.3 ohm/km AT 20 °C Reactance, approx 0.126 ohm/km AT 50 Hz Current rating, short-circuit 0.54/0.24/0.17 kA (0.1/0.5/1.0 s) Temperature rating, conductor 70 °C (OPERATING) 160 °C (SHORT CIRCUIT) Test voltage 2000 Vac Temperature range , ambient -40 TO +40 °C Relative humidity 98% AT 35 °C Installation temperature -15 °C (WITHOUT PRE-HEATING) Nominal tensile load 14.7 N Weight, approximate 150 kgs/km Service life 10 YR (MIN) Warranty rated life 2 YR (MIN) Current rating 18.5 А (IEC 60364-5-52 / GOST R 50571-5-52) Fire safety requirements: 1. Fire hazard category (cable marking) А 2. The toxicity index of combustion products > 40 g/m³ 2. Smoke Density (minimum light transmission) > 50% Resistance to external factors: Climatic modification and placement category U/UHL 4 GOST 15150 By agreement with the customer, it is allowed to change the climatic modification and placement category depending on the laying conditions Resistance to alternating bending deformations, cycles (movements), not less than Operation requirements: 1. Place of operation: Onshore technological complexes the cables in all respects, be suitable for operation in conditions prevailing within a typical petrochemical facility and the stated service conditions where the atmosphere shall be regarded as saliferous and corrosive, as commonly encountered in installations in close proximity to the 2. Appointment: The wires are designed to connect electrical machines and appliances for domestic and similar use to the electrical network. Compliance with regulatory requirements: 1. IEC 60227-5 or GOST7399 (Requirements for the construction, size and testing) 2. IEC 60332 - 3-22/ GOST IEC 60332-3-22 (flame spread test on bunched cables) 3. EN 50305/GOST 12.1.044 (Checking the toxicity index of combustion products) 4. IEC 61034-2/ GOST IEC 61034-2 (Smoke emission test) 5. The tests at low temperature shall be done in accordance with IEC 60811-506 for cold impact and IEC 60811-504 for cold bending or IEC 60811-505 for elongation at break when the cable is not subjected to bending test. The tests shall be carried out at a test temperature of (-40 +/- 2) °C for the cold bending and at (-35 +/- 2) °C for the cold impact test. Notes: 1. Any deviations from the stated requirements must be communicated to the Customer and agreed. 2. Manufacturer shall list in his quotation the type tests and routine tests to which his cables are Subjected Abbreviations: 1. Cu - сopper 2. PVC - polyvinyl chloride Type tests: Tests made before supplying, on a general commercial basis, a type of cable covered by this standard, in order to demonstrate satisfactory performance characteristics to meet the intended application Routine tests: Tests made by the manufacturer on each manufactured length of cable to check that each length meets the specified requirements Recommended for purchase in Russian Federation VENDOR DOCUMENT REQUIREMENTS: A01 Vendor Master Data Schedule (VMDS) B07 Vendor's Declaration of Compliance H18 Catalogue Data K04 Factory Acceptance Test (FAT) Report K38 CU TR Certificate , Declaration of Conformity for Low Voltage Equipment K39 RF , CU TR fire Safety Certificate of Conformity L04 Quality Management Accreditation eg ISO 9000 (including any manufacturing licenses held by Vendor, e.g. API, ASME etc.) N01 Installation, Commissioning, Operating & Maintenance Manuals P06 Preparation for Shipping with Recommended Handling, Storage & Preservation Procedures |
CBL ELEC ARM FIRE,3CX4AWG,0.6/1KV,BLK Cable, Electrical, Armoured, Fire spec Voltage 0.6/1 kV Design spec IEEE 1580 AND UL 1309 Mat spec, insulation IEEE 1580, TYPE P UL 1309, X110 Mat spec, outer sheath IEEE 1580 AND UL 1309, TYPE N Colour, outer sheath BLACK Number, cores 3 C Cross section, cores 4 AWG Cable designation TPNBS |
CBL ELEC ARM FIRE,600/1000V,4PR,16AWG Cable, Electrical, Armoured, Fire spec Flammability properties FLAME RETARDANT Voltage 600 / 1000 V Design spec IEEE 1580 AND UL 1309 Mat spec, insulation IEEE 1580, TYPE P UL 1309, X110 Colour, outer sheath BLACK Number, cores 4 PR Cross section, cores 16 AWG Cable, designation TP(IS-OS)PNBS |
Aspect | Armoured Cable | Unarmoured Cable |
Level of Protection | Armoured Cable has an additional level of protection made of metal, protecting it from physical damage, moisture, and other environmental factors. | There is no external protective layer in unarmoured cable, which makes it more vulnerable to damage from external factors. |
Cost | Armoured cables are more expensive due to the additional protective layer. | Unarmoured cable doesn't have any kind of protective layer, which is why it is less expensive. |
Applications | Armoured cables are suitable for use in hazardous environments, such as underground installations, areas with high moisture levels, and areas prone to mechanical damage. | Unarmoured cables are suitable for less demanding applications, such as inside walls or other protected locations. |
Underground Installation | Armoured Cables are ideal for direct burial and laying underground, protecting against environmental factors. | Unarmoured cables are unsuitable for burial or use in other applications and installations. |
Contact Us for Price List: Email: info@qingzhou-cable.com